Thickness | Standards | Unit | 3 mm | 4 mm | |||
Thickness of |
|
| [mm] | 0.5 | |||
Weight |
|
| [kg/m²] | 5.9 | 7.6 | ||
Width |
| | [mm] | 1250 / 1500 | |||
| |||||||
Technical properties | |||||||
Section modulus | W | DIN 53293 | [cm³/m] | 1.25 | 1.75 | ||
Rigidity | E·J | DIN 53293 | [kNcm²/m] | 1250 | 2400 | ||
Alloy / Temper of |
| EN 573-3 |
| EN AW 5005A (AIMg1) | |||
Modulus of Elasticity |
| EN 1999 1-1 | [N/mm²] | 70.000 | |||
Tensile Strength of Aluminium |
| EN 485-2 | [N/mm²] |
| |||
0.2 % Proof Stress |
| EN 485-2 | [N/mm²] |
| |||
Elongation |
| EN 485-2 | [%] |
| |||
Linear Thermal |
| EN 1999 1-1 |
| 2.4 mm/m at 100ºC temperature difference | |||
| |||||||
Core | |||||||
Mineral compound, polymer bonded | |||||||
| |||||||
Surface | |||||||
Lacquering |
|
|
| Coil Coating | |||
Gloss (initial value) |
| EN 13523-2 | [%] | 30-80 | |||
Pencil Hardness |
| EN 13523-4 |
| HB-F | |||
| |||||||
Acoustical Properties | |||||||
Sound Absorption Factor | αs | ISO 354 |
| 0.05 | |||
Sound Transmission Loss | Rw | ISO/DIS 717-1, | [dB] | 27 | 27 | ||
Loss Factor | d | EN ISO 6721 |
| 0.004 | 0.005 | ||
| |||||||
Thermal Properties | |||||||
Thermal Resistance | R | DIN 52612 | [m²K/W] | 0.002 | 0.003 | ||
Heat Transition | Λ* | DIN 4108 | [W/mK] | 1.5 | 1.33 | ||
Coefficient | U | DIN 4108 | [W/m²K] | 5.81 | 5.78 | ||
Temperature Resistance |
|
| [ºC] | -50 to +80 | |||
| |||||||
Wind load and permissible panel sizes
ALUCOBOND® A2 3 mm | ALUCOBOND® A2 4 mm | |
|
| |
The graphs for 3 mm and 4 mm thick ALUCOBOND® A2 indicate the maximum permissible panel length (σ = 53 N/mm²) (without having to add a stiffener) based in applicable design wind load and panel width. Values apply to 4-side supported panels. Values for other systems on request.